HAEMONETICS 0.9 % SODIUM CHLORIDE- sodium chloride solution মার্কিন যুক্তরাষ্ট্র - ইংরেজি - NLM (National Library of Medicine)

haemonetics 0.9 % sodium chloride- sodium chloride solution

haemonetics corporation - sodium chloride (unii: 451w47iq8x) (sodium cation - unii:lyr4m0nh37) - sodium chloride 900 mg in 100 ml - sodium chloride injection, usp is indicated as a source of water and electrolytes. 0.9% sodium chloride in hemodialysis procedures. none known safety and effectiveness of sodium chloride injection, usp in pediatric patients have not been established by adequate and well controlled trials; however, the use of sodium chloride solutions in the pediatric populations is referenced in the medical literature. the warnings, precautions and adverse reactions identified in the label copy should be observed in the pediatric population.  do not administer unless solution is clear and seal is intact.

HAEMONETICS ANTICOAGULANT CITRATE DEXTROSE SOLUTION- anhydrous citric acid, trisodium citrate dihydrate, dextrose monohydrate so মার্কিন যুক্তরাষ্ট্র - ইংরেজি - NLM (National Library of Medicine)

haemonetics anticoagulant citrate dextrose solution- anhydrous citric acid, trisodium citrate dihydrate, dextrose monohydrate so

haemonetics corporation - anhydrous citric acid (unii: xf417d3psl) (anhydrous citric acid - unii:xf417d3psl), trisodium citrate dihydrate (unii: b22547b95k) (anhydrous citric acid - unii:xf417d3psl), dextrose monohydrate (unii: lx22yl083g) (anhydrous dextrose - unii:5sl0g7r0ok) -

Haemonetics NEO Neonatal High Efficiency Leukocyte Reduction Filter for Red Blood Cells with Attached 175ml PVC Aliquot Bag with সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics neo neonatal high efficiency leukocyte reduction filter for red blood cells with attached 175ml pvc aliquot bag with

transmedic pte ltd - general hospital - the haemonetics neo neonatal high efficiency leukocyte reduction filter for red blood cells with attached 175ml pvc aliquot bag with needleless injection port reduces the levels of leukocytes and microaggregates from up to 60ml of packed red blood cells.

Haemonetics Cell Saver 5+ Autologous Blood Recovery System সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics cell saver 5+ autologous blood recovery system

transmedic pte ltd - hematology - the haemonetics cell saver 5+ system and its related accessory devices are intended to be used for recovery of blood shed during or after an operation, or as the result of trauma, processing the blood by a centrifugation and washing procedure and pumping this processed red cell product to either a bag for gravity reinfusion into the patient or to the arterial line of an extracorporeal circuit for reinfusion into the patient. the cs5+ system should be considered for a procedure when it is anticipated that blood will be shed from a clean wound and retrieved at a rate permitting aspiration without undue hemolysis. the presence of any of the following criteria may be an indication for blood salvage: • anticipated blood loss is 15% or more of the patient’s estimated blood volume. • blood would ordinarily be crossmatched. • more than 10% of the patients undergoing the type of procedure require transfusion. • the mean transfusion rate for the type procedure exceeds one unit.

Haemonetics Acrodose™ PLus System সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics acrodose™ plus system

transmedic pte ltd - hematology - intended for pooling of abo identical, whole-blood-derived cpd or cp2d platelet concentrates and sampling for bacterial testing of the pooled platelets using the integral ebds sample set.

Haemonetics Blood Transfusion Filters সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics blood transfusion filters

transmedic pte ltd - general hospital - free-flow, low priming volume device which provides a 40 μm rated screen filter medium for the removal of potentially harmful microaggregates from stored blood, fresh blood, red cells, platelet and granulocyte concentrates, cryoprecipitates, plasma and plasma fractions and for filtration of viaspan (cold storage solution). the filter is also useful for reducing the incidence of febrile reactions and thrombocytopenia, following blood transfusion.

Haemonetics BPF4 Post-Process Filter System for Red Cells সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics bpf4 post-process filter system for red cells

transmedic pte ltd - hematology - indicated for the removal of leucocytes, platelets, and microaggregates from a single unit red cells or whole blood. when used with a sterial connection device, permits subsequent storage of blood products with no change to original expiry date.

Haemonetics High Efficency Post-Process Filter System for Leucocyte Removal from Red Cells সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics high efficency post-process filter system for leucocyte removal from red cells

transmedic pte ltd - general hospital - indicated for the removal of leucocytes, platelets, and microaggregates from a single unit of red cells or whole blood.

Haemonetics High Efficiency Post-Process Filter System for Leucocyte Removal from Red Cells সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics high efficiency post-process filter system for leucocyte removal from red cells

transmedic pte ltd - hematology - indicated for the removal of leucocytes, platelets and microaggregates from a single unit of red cells. when used with a sterile connection device, permits subsequent storage of blood product with no change to original expiry date. filtration must be performed within 7 days of donation. for blood bank use.

Haemonetics Leukotrap RC Blood Collection System with In-Line Filter সিঙ্গাপুর - ইংরেজি - HSA (Health Sciences Authority)

haemonetics leukotrap rc blood collection system with in-line filter

transmedic pte ltd - hematology - intended for collection of 450ml of blood and preparation of platelets, plasma, and pre-storage leukocyte removal from red cells.